Duplex Inline Filter for Hydraulic Systems 1. Filter Housing Construction The filter housings are designed in accordance with international regulations. The two sections of the filter housing (each with bolt-on cover plates) are connected by means of a ball change-over valve with negative overlap and single lever operation (ball, segment). 2. Filter Element 2.1 Filter elements are validated with all ISO standards: ISO 2941, ISO 2942, ISO 2943, ISO 3724, ISO 3968, ISO 11170, ISO 16889 2.2 The max allowable pressure drop: Glass Fiber (BN/HC): 20 bar Paper (P/HC): 10 bar Wire mesh (W/HC): 20 bar Stainless steel fiber (V): 210 bar 2.3 Filtration rating in μm: BN/HC, V: 3, 5, 10, 20 P/HC:10,20 W/HC: 25, 50, 100, 200 3.General Mounting: Filters must be flexibly mounted and not fixed rigidly to the floor or used as a pipe support. Flow: Inlet: top Outlet: bottom Temperature range: -10℃ to +100 ℃ Setting pressure of clogging indic…